| STANDBY POWER(KVA) |
70 |
| STANDBY POWER(KW) |
55 |
| RATED POWER(KVA) |
63 |
| RATED POWER(KW) |
50 |
| POWER FACTOR |
0.8 |
| OUTPUT VOLTAGE(V) |
400/230 |
| MAXIMUM OUTPUT CURRENT(A) |
90 |
| GENSET DIMENSION(L×W×H)(mm) |
1800×710×1350 |
| WEIGHT(kg) |
802 |
| ENGINE (PERKINS) |
|
| MODEL |
1004TG |
THE MAXIMUM OUTPUT POWER(kW) |
72.3 |
| THE NO.OF CYLINDER |
4L |
FUEL CONSUMPTION(g/kw.h) |
220 |
| BORE/STROKE(mm) |
100/127 |
DISPLACEMENT(L) |
3.99 |
| EXHAUST AIR FLOW(m3/min) |
160 |
COMPRESS AIR FLOW(m3/min) |
4.3 |
| EXHAUST GAS FLOW(m3/min) |
11.7 |
EXHAUST GAS HIGHEST TEMPERATURE(℃) |
519 |
| LUB-OIL PAN CAPACITY(L) |
8.1 |
ING WATER CAPACITY(L) |
19.7 |
| VOLE FOR START(V) |
24 |
INSTRUMENT FOR ADJUSTING SPEED |
MECHANICAL |
| NOISEdb(A) |
≤92 |
|
|
| ALTERNATOR (LEROY SOMER) |
| MODEL |
LSA43.2L65 |
EXCITATION |
BRUSH-LESS |
| INSULATION CLASS |
H |
VOLTAGE ADJUST RANGE |
≥±6% |
| FROTECTION CLASS |
IP23 |
STEADY STATE VOLTAGE REGULATION |
≤±0.5% |
| EFFICIENCY |
90.30% |
VOLTAGE CONTROL |
AVR |
|