STANDBY POWER(KVA) |
34 |
STANDBY POWER(KW) |
28 |
RATED POWER(KVA) |
31 |
RATED POWER(KW) |
25 |
POWER FACTOR |
0.8 |
OUTPUT VOLTAGE(V) |
400/230 |
MAXIMUM OUTPUT CURRENT(A) |
45 |
GENSET DIMENSION(L×W×H)(mm) |
1650×650×1400 |
WEIGHT(kg) |
710 |
ENGINE (DEUTZ) |
MODEL |
D226B-3 |
THE MAXIMUM OUTPUT POWER(KW) |
33 |
THE NO.OF CYLINDER |
3L |
FUEL CONSUMPTION(g/kw.h) |
220 |
BORE/STROKE(mm) |
105/120 |
DISPLACEMENT(L) |
3.12 |
EXHAUST AIR FLOW(m3/min) |
155 |
COMPRESS AIR FLOW(m3/min) |
2.83 |
EXHAUST GAS FLOW(m3/min) |
6 |
EXHAUST GAS HIGHEST TEMPERATURE(℃) |
470 |
LUB-OIL PAN CAPACITY(L) |
7.75 |
ING WATER CAPACITY(L) |
17 |
VOLE FOR START(V) |
24 |
INSTRUMENT FOR ADJUSTING SPEED |
MECHANICAL |
NOISEdb(A) |
≤102 |
|
|
ALTERNATOR (LEROY SOMER) |
MODEL |
LSA43.2S1 |
EXCITATION |
BRUSH-LESS |
INSULATION CLASS |
H |
VOLTAGE ADJUST RANGE |
≥±6% |
FROTECTION CLASS |
IP22/IP23 |
STEADY STATE VOLTAGE REGULATION |
≤±0.5% |
EFFICIENCY |
89% |
VOLTAGE CONTROL |
AVR |
|